Smart Temporary Power Distribution Box · Y952
Temporary Power Distribution with Local Protection and Monitoring
Y952 integrates a mobile secondary distribution box, local electrical protection and a connected temporary-power monitoring system for construction sites, exhibitions and outdoor events.
- Mobile temporary-power distribution
- Three standard safety functions
- 4G and Wi-Fi connectivity
- Five project-option groups
Remote monitoring and notifications do not replace the local electrical protection devices or the site's safe-isolation procedure.

Product architecture
One Box for Temporary Distribution, Protection and Status Monitoring
Y952 is intended for temporary installations that move, change or redeploy. It keeps electrical protection local while reporting selected operating states through the connected monitoring system.
Temporary secondary distribution
Organize incoming supply, outgoing circuits and field connections in a mobile box designed for repeated deployment.
Local electrical protection
Address confirmed connector, electric-shock, voltage and phase-sequence risks through local devices and project configuration.
Status and exception awareness
Collect configured states, identify defined exceptions and support notification and event-record workflows.
Standard safety scope
Three Local Protection Functions Address Different Risks
Exact detection items, thresholds, trip actions and recovery logic are defined by the selected product and project documents.
Smart connector
Supports temporary connection workflows and configured connector-state monitoring, including notification when a monitored disconnection occurs.
Electric-shock protection
Provides local protection for the confirmed electric-shock risk and circuit configuration.
Voltage and phase sequence
Detects configured voltage and phase-sequence exceptions and responds according to the approved product configuration.
Local protection remains local: a lost network may affect remote visibility and notification, but it does not turn cloud monitoring into the electrical protection path.
Temporary-power monitoring
Separate Detection, Protection, Notification and Recovery
These are distinct functions. The monitoring interface must not imply that every detected exception automatically opens a circuit.
Project options
Add Only the Functions the Site Requires
These options are not part of every standard box. Confirm the need, monitored point and expected response for each one.
Smart lock
Control or record authorized access to the distribution-box door.
GPS
Support location management for mobile or distributed boxes.
Energy meter
Measure defined electrical values on selected circuits.
Alarm and power-loss monitoring
Add local audible-visual notification and defined supply-loss detection where required.
Project selection
Confirm the Electrical System, Risks and Monitoring Scope
A product image is not enough for selection. The circuit and safety design must match the actual temporary-power installation.
Application and movement
Construction, exhibition or outdoor event; deployment frequency and handling method.
Power and earthing
Voltage, phase, capacity, earthing, incoming supply and outgoing connections.
Loads and connectors
Main and branch circuits, load list, spare circuits and connector quantity.
Risks and response
Required protection, monitoring, notification, records, recovery and acceptance evidence.
FAQ
Safety, Monitoring and Project Options
What is the Y952 Smart Temporary Power Distribution Box?
Y952 is a mobile secondary temporary-power distribution box for construction sites, exhibitions and outdoor events. It combines field distribution, local electrical protection and connected monitoring.
Is Y952 a complete box or a monitoring terminal for an existing box?
Y952 is delivered as a complete mobile temporary-power box. The box handles distribution, connections and local protection; the monitoring system collects status, identifies configured exceptions and supports notifications and event records.
Which safety functions are standard?
The standard scope includes a smart connector, electric-shock protection, and voltage and phase-sequence protection. Detection items, thresholds, actions and recovery behavior must be confirmed in the applicable product and project documents.
What does the temporary-power monitoring system monitor?
It monitors configured connector, protection, power-supply and equipment states. The available fields, circuit scope, notifications and records depend on the selected configuration; not every model includes every electrical measurement.
Does detecting an abnormal condition mean the circuit has been disconnected?
No. Monitoring, local indication and remote notification communicate the condition. Circuit interruption depends on the relevant local protection device and confirmed product configuration.
Does Y952 support 4G and Wi-Fi?
Yes. 4G and Wi-Fi provide the standard communication basis. Network access, platform features, records and any offline behavior must be confirmed for the selected configuration.
Are the smart lock, GPS, meter, audible-visual alarm and power-loss monitoring standard?
No. These are project options for access control, location, energy measurement, local notification and defined power-loss detection.
What information is needed to select a Y952 configuration?
Provide the application, supply, earthing, circuit and load list, connector count, environment, monitored states, network conditions, local alarm needs and acceptance requirements.
Project review
Share the Supply, Circuits, Loads and Site Safety Requirements
Provide the application, electrical system, connector and load list, environment, monitored states, network conditions and options so the technical team can review the Y952 configuration.